Release 1.7.0

    1) Add detailed information from Seg2 header to print preview
    2) Optimize Application Setup for Windows 64 bit and Windows 32 bit
    3) Optimize View Properties Dialog for SUMMIT X Stream Pro
    4) Amplitude values ​​between +/- 0.0001 mV will be represented in exponential notation.
    5) Bug fix: Save Record with uniform filestring.
    6) Bug fix: Check AGC Window length
    7) Feature: Reverse station order in Assign Station(s)

Release 1.6.0

    1) Bug fix: Close Control Tabs after System check
    2) Bug fix: Trigger Force for doubble allocation.
    3) Feature: Lock Parameters for Recording Parameter and Shooting Parameter

Release 1.5.0

    1) Additional support of sampling rates: 1/96 and 1/192. This option is only available with special hardware. For more details, please feel free to contact our Summit Team.
    2) Fast correlation option. Now it is possible to accelarate the correlation time by 13 times. To use this feature it is neccessary to update the firmware in your Summit Units. Please contact our Summit Team for support.
    3) Bug fix: Open corrupt survey files
    4) Feature: Context menu for spread actions.

Release 1.4.0

    1) Application, Driver and Setup for Windows 64 bit and Windows 32 bit

Release 1.3.2

    1) Bug fix: System Check shows wrong information for disconnected boxes.
    2) Bug fix: Box goes down during system check - Spread is still green
    3) Bug fix: Shooting and test function with lowest trace length fails
    4) Bug fix: SetUnitList fails with chinese characters
    5) Seg2 File Names with format: Prefix_#####.sg2. Thus all files are sorted properly.
    6) Bug fix: Handle corupt Survey Files properly: A new survey File must be created

Release 1.3.1

    1) Bug fix: System Check shows zero values: Slow Spread Scan for System Check -> All commands are executed
    2) Resending multiple Prepare commands in case of a transfare failure
    3) Record Sheet: Information about line communication Problems: Prepare Command
    4) Record Sheet: Information about identical traces -> Hint for line communication problems
    5) Seismic Viewer: Identical Traces are highlighted with red color

Release 1.3.0

    1) Fast Spread Scan
    2) Bug fix: Noise Monitor for Active Spread including disconnected Units
    3) Add: Read Repeater Line and Station from Box
    4) Automatic Geometry Allocation by Unit Address List
    5) Seg2 Data: SUMMIT Box Address new format: xx yy instead of xx-yy: Reason Segy Converter does not accept char '-'
    6) Add: Option to fix Zoom Window in View Parameter Dialog

Release 1.2.1

    1) Improved bug tracking in separate thread mode

Release 1.2.0

    1) Release for Windows 7 including new driver compilation
    2) Improved bug tracking system

Release 1.1.1

    1) Feature: Update Check uses default proxy settings

Release 1.1.0

    1) Feature: Shearwave acquisition option: The polarity of each shot can be changed even during stacking. (Note: An update of your SUMMIT Box firmware is required too)
    2) Bug fix: working with unallocated stations causes error message when clicking Enable Trigger button.
    3) Bug fix: View Properties in Seismic Window: AGC Window change did not update the record view
    4) Bug fix: View Properties in Seismic Window: Values are not saved properly "Set as default button"
    5) Setup: The setup is now deployed as a selfextracting archive.
    6) SUMMIT USB Driver: New version, compiled for Windows XP and Windows Vista

Release 1.0.0

    1) Creation of final Release

Release 0.1.6

    1) Bug fix: Save Button in Acquisition Console was enabled at wrong shooting states
    2) Bug fix: Manual Save in Acquisition Console stores wrong shot station number
    3) Feature: Add the option to fix the last active station during roll along
    4) Feature: Add Receiver Gap options: Working with a fix gap or a gap that moves with the source

Release 0.1.5

    1) Bug fix: Setup of 0.1.4 contains old files

Release 0.1.4

    1) New Option: View Porperties Trace Range is selectable as full range
    2) Refactor: Get rid of seismic filter unmanaged components
    3) Record Sheet: Replace "Sampling Rate" with "Recording Time"
    4) AppCollection: Bug fix: Splash and About Form: hides "&"
    5) Add Software Version to Seg2 file
    6) Bug fix: Dynamic Help -> now Files are copied to data Path

Release 0.1.3

    1) Html Test results: Add Titel row
    2) Shooting and multiple reread: Bug fix time for wait window.
    3) Add seismic header for printing
    4) Bug fix: Corrupt Survey Info File throws exception according corrupt SUMMIT Address List file
    5) Introduce: Automatic Backup system for survey files
    6) Introduce: Save chart files as images
    7) Bug fix: Enable Trigger Button looses focus in case of undocked Acquisition Console Window
    8) New option: Save Seismic View Properties as default

Release 0.1.2

    1) Introduce: Automatic Update Check

Release 0.1.1

    1) Add: Auto Save
    2) Include Help Document
    3) Select: Active Spread
    4) Add HelpDocumentFiles to Setup Process
    5) Apply negative Source Station Numbers
    6) Redesign of storing default survey and seismic data
    7) Implement: Storing uncorrelated data for correlation on PC Site
    8) Bug fix: Dead lock in case of unsing aux channels and try to do reread
    9) Recording / Shooting Parameter: Automatically adapt combobox values in case of custom entry
    10) Bug fix: Timing for registration
    11) Bug fix: Add normalisation for correlation trace
    12) Bug fix: Battery check for Compact Units. When disconnected battery level: 100%
    13) Adapt registration parameter for aux module properly, in case of switching the aux channel
    14) Bug fix: Bug tracker
    15) Add dimensions to Registration Parameter
    16) Remove spelling mistakes
    17) Introduce special spread symbol for Aux-Channels
    18) Improve Assign Station Dialog
    19) Bug fix: Storing All Channel Parameter
    20) Bug fix: Missing callback according changing Aux Channel Paramerter after restart application
    21) Change Source Output Delay from samples to ms
    22) Introduce Actual Source Output Delay to crosscheck the value for all Channels
    23) Introduce Prefix File Name for storing individual seismic file names
    24) Function Test: Introduce sort by station or by channel list
    25) Add: Correlation by with Aux Channel on Pc Site
    26) Bug fix: Diversity Stack

Release 0.1.0

    1) First Beta-Release

Release 0.0.11

    1) Spread
    1.1) Sort by X-Order. Thus the spread symbols overlap linear.
    1.2) Bug fix: Using Pocket PC Allocation: Remove Box a and replace it with Box B (same stations) => Double Allocation
    1.3) Fix Zoom Option
    1.4) Show Diconnected Repeater
    2) Record Sheet: Bug fix: Desired Stack count is displayed and not actual
    3) Function Test: Warning for Geophone Check -> Active Hydrophones may be damaged
    4) Redesign System and Geophone Check
    4.1) Add Option to sort by: Address, Station
    4.2) Add FirwareCheck as Table
    4.3) Add USB Serial Number and Firmware Number to FirwareCheck
    4.4) Remove USB Serial Number and Firmware Number from Channel List
    4.5) Add System Check Overview as table
    4.6) Add Geophone Check Overview as table
    5) Add Repeater Battery Check
    6) Bug fix: Reater State after Stop and Start Scan: is still red
    7) Support Repeater Expert mode: CRC Infos
    8) Bug Fix: Recording Parameter: Aux Module: PreTrigger: Dimension [samples] change to [ms]
    9) Add SurveyName to TitleBar
    10) Change AppDataPath to User Home Directory to store Application User Data
    11) Seismic Channels: Add "Connected" Column
    12) Context Menu: Seismic Channels: Add: "Invert Selection"
    13) Menu View: Add "Restore Default Window Layout"
    14) Adapt TimeAccuracy Threasholds

Release 0.0.10

    1) Convert to VS 2008
    2) Time Accuracy
    2.1) Now in ppm
    2.2) Now with threasholds
    3) SUMMIT Unit Form: Bug fix: enter faulty unit address and return: Form closes
    4) Remove Leakage Test from Geophone Tests

Release 0.0.9

    1) Function Tests
    1.1)Bug Fix: Null Traces becauce of timing problem for short recording times
    2) Redesign: Coordinate Mapping for Stations is stored now in Station instead of SUMMIT Box

Release 0.0.8

    1) Seismic Channel List
    1.1) Bug fix: Context Menu Entry "Test" is enabled although no channel is selected
    2) Funktion Test
    2.1) Bug fix: Exception with no connected USB Interface
    2.2) Storing last Parameter

Release 0.0.7

    1) Survey
    1.1) Bug fix: Open Survey -> Spread is in sleep mode
    1.2) Bug fix: Create new Survey -> Spread is in sleep mode
    1.3) Bug fix: Remove multiple callbacks of Spread Chart

Release 0.0.6

    1) Fix: Spelling Mistakes
    2) Improve Help Info for Porperty Grids: Shooting and Recording Paramter
    3) Spread
    3.1) Status Sleep, Stop: Now Spread is gray colored
    3.2) Bug fix: Click on "Show Repeater" in "Sleep Status", geophone stations get green
    3.3) Bug fix: Send Sleep to Compact Unit: After wake command Compact Unit is still in sleep mode
    4) Instrument Test:
    4.1) No Test while in sleep mode
    5) Shooting
    5.1) Bug fix: Acquisition dialog blocks application in Stack Preview Mode = Complete
    5.2) Bug fix: Acquisition dialog show wrong times for shooting parameter
    6) Shooting Parameter
    6.1) Bug fix: Entry "Auto Reallocation Mode" gets enabled after shooting

Release 0.0.5

    1) Record Sheet
    1.1) Add Column: Stacks
    2) Function Test
    2.1) Bug Fix: Listening Time changed, when sampling rate was changed
    3) Recording Parameter
    3.1) Bug Fix: Listening Time changed, when sampling rate was changed
    3.2) Bug Fix: Auxillary PreTrigger ComboBox shows times depending on sampling rate
    of regular channels

Release 0.0.4

    1) Spread
    1.1) Repeater: Possible to set odd station and line values
    1.2) Colors changed: Gray Color removed. Now: Red stands for unallocated station and disconnected but allocated station
    2) Record Sheet
    2.1) Bug fix: Column "Date" was sortable
    3) Shooting
    3.1) Bug fix: SEG File: Wrong station and line number for non allocated stations

Release 0.0.3

    1) System Check, Geophone Check:
    1.1) Bug fix: Adding tab paged twice, after creating a new survey
    2) Noise Monitor
    2.1) Bug fix: Wrong address order by selecting "connected units"
    3) Record Sheet
    3.1) Bug fix: Sampling Count is stack preview value
    4) Shooting
    4.1) Enable shooting with unallocated stations

Release 0.0.2

    1) Record Sheet:
    1.1) Disable editing of all columns, except: "Comment"
    1.2) Add "Date" column
    1.3) HTML Record Sheet: same column order like Data Grid
    1.4) Bug fix: clear Data Grid entry when opening a new survey
    2) Spread:
    2.1) Disable Spread while shooting: Gray colored chart
    3) Noise Monitor:
    3.1) Bug fix: vertical position of chart
    4) Acquisition Console:
    4.1) Disable reread button while noise monitor is active
    5) Shooting Parameter:
    5.1) Add backup output directory

Release 0.0.1

    1) First Release: Alpha